BAS Integration Toronto

Cold Fuel connects rooftop units, make-up air units, drives and refrigeration controllers to one building automation system (BAS) over BACnet and Modbus. Commercial buildings across Toronto and the GTA get open-protocol integration, with every point tested at handover.

  • Points List Agreed Before Any Wiring
  • Open Protocols With No New Vendor Lock-In
  • Every Point Tested at Handover

Open-Protocol Building Automation Integration in Toronto

Integration makes existing controllers report to a single platform, so schedules, set points and alarms are managed in one place. Each controller speaks a protocol. BACnet, published by ASHRAE as Standard 135 and adopted as ISO 16484-5, is the most common open standard for commercial HVAC controls. Modbus is common on drives, meters and refrigeration controllers. Our technicians map what each controller can share, add gateways where protocols differ and connect the points your operators actually use.

  • Controller survey: make, model, firmware and protocol of every controller in scope.
  • Points list: temperatures, statuses, set points and alarms agreed for each unit.
  • Gateways and wiring: network cabling and protocol gateways where devices cannot talk directly.
  • Graphics and alarms: equipment screens, schedules and alarm priorities set up in the BAS.

Every Project Starts With a Points List

Before any wiring, we walk the building and list every controller, its protocol and the points it can share. You get a points list for each unit showing what the BAS will read, what it will be allowed to change and which alarms it will raise. Nothing is connected until that list is agreed with your facility managers or controls contractor.

The work happens one unit at a time, so equipment keeps running on its own controls until it is switched over. After handover, our 24/7 line covers both the integration and the rooftop units, refrigeration and drives connected to the BAS, because we service that equipment too.

team
Since 2010 Top Rated Mechanical Services
4.9 (72)

Trusted by 500+ businesses across Ontario

Same-Day HVAC Service Licensed & Insured EPA-608 • NATE-Certified Residential & Commercial

Integration Across HVAC and Refrigeration

Integration is only as good as the equipment behind it, and we work on that equipment as well as its controls.

Walk-In Freezer

Walk-in controllers that report box temperature and defrost status to the BAS.
Walk-In Freezer
Repair Installation Maintenance

Commercial Fridge

Reach-in and case alarms added to the building's alarm list.
Commercial Fridge
Repair Installation Maintenance

Commercial Heating

Make-up air and unit heater schedules run from the BAS.
Commercial Heating
Repair Installation Maintenance

Commercial Cooling

Packaged and split cooling units started and stopped on the BAS schedule.
Commercial Cooling
Repair Installation Maintenance

Rooftop AC Unit

Rooftop unit set points, economizer position and faults on one screen.
Rooftop AC Unit
Repair Installation Maintenance

Commercial Freezer

Freezer temperatures logged alongside the rest of the building's equipment.
Commercial Freezer
Repair Installation Maintenance

True Refrigeration, Atosa, Silver King, Randell, QBD, Omcan, Nella, Master-Bilt, Manitowoc, Kelvinator, Ice-O-Matic, Hoshizaki, Habco, Beverage-Air, Arctic Air, KeepRite, Copeland and Trenton. Our technicians also service the rooftop and cooling equipment in the same buildings, so one company handles both the refrigeration and the HVAC on your site.

Building Systems We Integrate in Toronto

Most buildings already have the equipment. What they lack is one place to see and control it. These are the integrations we handle most often.

Refrigeration Controllers

Walk-in and rack controllers report box temperatures, defrost status and alarms. Refrigeration settings stay in the refrigeration controller, and the BAS reads them and raises the alarms.

What Sets Our Integration Work Apart?

A controls problem and an equipment problem often look the same on the screen. With Cold Fuel’s 15+ years on GTA roofs and in machine rooms, our technicians can tell which one they are looking at.

Expertise & Experience

Technicians who know the controller and the equipment it runs.

Tailored Solutions

Points, graphics and alarms chosen for how your operators work.

Rapid Response Support

24/7 support for the BAS and the equipment connected to it.

No Point Goes Live Until It Has Been Tested

Each point on the list is checked from both ends. We send a command from the BAS and confirm the equipment responds, then compare each reading on the BAS screen with the value on the unit’s own display. Alarms are triggered on purpose to confirm they arrive with the right priority.

Where the owner has a naming and trending standard, we follow it. The City of Toronto, for example, publishes a Standard Building Automation System Specification for its own buildings, and many owners use something similar.

01
Electrical panel, breakers and wiring components

BACnet

The most common open protocol for HVAC controllers.

02
Floor drains and drainage piping components

Modbus

Common on drives, meters and refrigeration controllers.

03
Ventilation fans, ducting and air diffusers

Protocol Gateways

Translate between protocols when two devices cannot talk directly.

These are the building automation problems we see most often:

  • Units fighting each other: one rooftop unit heating while the next one cools the same space, which raises operating costs and hurts occupant comfort.
  • Wrong schedules: equipment running all weekend or starting an hour late after a time change.
  • Alarm floods: hundreds of low-priority alarms that hide the one that matters.
  • Unsupported controllers: old controllers with no parts, no software and no one who can change them.
  • Sensor drift: temperature sensors reading several degrees off and driving equipment the wrong way.
  • Vendor lock-in: settings that only one company can change.

Equipment from KeepRite, Copeland, Trenton and the other brands we work with is connected through its own controller or a gateway. Our clients include offices, retail plazas, grocery stores and cold storage facilities.

Integration Is Priced by Points, Not Floor Area

Two buildings of the same size can need very different integration work, so we quote after the controller survey. The survey and estimate are free, and the scope you sign lists controllers, gateways, wiring and programming hours.

What affects the cost:

  • Number of controllers and points to integrate
  • Protocols in use and the gateways needed
  • Whether the existing BAS is open or proprietary
  • Graphics, trending and alarm setup

Save on Energy’s Retrofit program, run by the IESO, includes an Advanced Rooftop Unit Controls measure: demand control ventilation with variable-speed supply fan control on a single-zone rooftop unit that already has a working economizer. We check whether your units qualify before the quote.

Stainless steel commercial refrigerators in a kitchen

Looking for Parts?

Reach out for expert support, fast sourcing, and competitive pricing.

Keep Working Controllers, Replace Only the Old Ones

Replacing building automation systems outright is rarely the first step. Controllers that still work and speak BACnet or Modbus can stay, and only the unsupported ones are replaced. Under Toronto’s energy and water reporting by-law, buildings of 50,000 square feet and larger already report energy and water use, and buildings from 10,000 to 49,999 square feet begin mandatory reporting in 2027. Meters and trend logs in the BAS make those numbers easier to pull together and show where energy efficiency can improve.

Building Automation Integration in Toronto and Surrounding Cities

Integration projects in downtown Toronto, East York, Scarborough, Markham, Stouffville and Vaughan are handled from our offices in Concord, Etobicoke, Mississauga and Toronto.

  • Offices and medical buildings: HVAC systems on schedules that match occupancy.
  • Retail plazas: tenant units with set points managed from one screen.
  • Grocery stores and supermarkets: refrigeration alarms alongside the HVAC equipment.
  • Cold storage and food processing: room temperatures and drive speeds logged together.

Book a Controller Survey

Send us a list of your rooftop units, drives and refrigeration controllers, or tell us what the current BAS can’t do, and we’ll walk the building and quote the work for free.

From Separate Controllers to One System

Every BAS integration project, large or small, runs through the same four steps.

Controller Survey

We record every controller in scope with its make, model, firmware and protocol. The survey also shows which controllers can stay and which should be replaced.

Points List and Quote

You get a points list for each unit and a written quote for gateways, wiring and programming. Nothing is ordered until you approve both.

Integration

Network wiring, gateways and controllers are installed and connected one unit at a time. Equipment keeps running on its own controls until it is switched over.

Commissioning and Training

Every point is tested from the BAS to the equipment and back, and every alarm is triggered on purpose. Your operators get a walk-through of the screens, schedules and alarms.

Technician wearing safety glasses servicing equipment
TSSA Level-1 certified technicians Code-compliant refrigeration connections
Trusted by Businesses Across Industries
Restaurants Bars Bakery Catering Supermarkets Grocery Stores Warehouses Hotels

Frequently Asked Questions

Not automatically. Two BACnet devices can support different object types and services, so we check what each device supports before we commit to a points list.

Our Service Areas